RF Power Supply and Matching Box
2. Overview
9
Classification Item
Specification value
RFS-13100L
Input
Phase, frequency
Three phase, 50/60 Hz
Input voltage
200 V/220 V
Fluctuation range
±
10 % (180 to 242 V)
Input capacity
15.5 kVA or less
Connector
CE05-2A32-17PD-B
Leakage current
5 mA or less
Output
Oscillation frequency 13.56 MHz
±
0.05%
Rated traveling wave
power
10 kW (at 50
Ω
load)
Maximum reflected
wave power
1000 W
Output impedance
50
Ω
Harmonic distortion -45 dB or less
Power stability
±
3% or less of rated output (10% to 100% of rated output)
Rise time
Minimum approx. 200 ms
Linearity
±
2% or less of rated output (10% to 100% of rated output)
Output connector
EIA 7/8
Cooling
Cooling method
Water c forced air cooling
Water temperature 5
°
C to 25
°
C (no condensation)
Water volume
8 L/min or higher *Alarm operates at cooling water volume
7.5 L/min or lower
(However, the alarm does not operate when RF-OFF)
Differential pressure Approx. 0.10 MPa (at 8 L/min)
Withstand pressure 0.96 MPa or less
Joint
PT-3/8
Water quality
See "Table 2-17 RF system cooling water - Water quality"
Exterior
Exterior dimensions 480 W x 600 D x 350 H or less (not including protrusions)
Configuration
Rack mount configuration
Weight
Approx. 70 kg
Table 2-5 RF power supply individual specifications