7
Classification Item
Specification value
RFS-1310L
RFS-1330L
Input
Phase, frequency
Single phase, 50/60 Hz
Three phase, 50/60 Hz
Input voltage
200 V/220 V
Fluctuation range
±
10% (180 to 242 V)
Input capacity
1.7 kVA or less
5 kVA or less
Connector
MS3102A 16-10P
Leakage current
3 mA or less
5 mA or less
Output
Oscillation frequency
13.56 MHz
±
0.05%
Rated traveling wave
power
1 kW (at 50
Ω
load)
3 kW (at 50
Ω
load)
Maximum reflected
wave power
200 W
300 W
Output impedance
50
Ω
Harmonic distortion
-45 dB or less
Power stability
±
3% or less of rated output (10% to 100% of rated output)
Rise time
Minimum approx
. 30 ms
Linearity
±
2% or less of rated output
(10% to 100% of rated output)
Output connector
HN connector
Cooling
Cooling method
Water cooled
Water temperature
5
°
C to 25
°
C (no
condensation)
Water volume
4 L/min or more
* When using the optional flow meter, the alarm operates at
a cooling water volume of 3.5 L/min or lower
(however, alarm does not operate when RF-OFF)
Differential pressure
Approx. 0.05 MPa (at 4
L/min)
Approx. 0.06 MPa (at 4 L/min)
Withstand pressure
0.96 MPa or less
Joint
PT-1/4
PT-3/8
Water quality
See "Table 2-17 RF system cooling water - Water quality"
Exterior
Exterior dimensions
240 W x 383 D x 150 H or
less
(not including protrusions)
240 W x 460 D x 150 H or less
(not including protrusions)
Configuration
Rack mount configuration
Weight
Approx. 12 kg
Approx. 20 kg
Table 2-3 RF power supply individual specifications