RF Power Supply and Matching Box
4. Functions
34
* Please prepare contacts with a capacity of 12 VDC and 12 mA or higher.
* If using semiconductor devices, please prepare devices with a leakage current 0.1 mA or lower.
* Caution when using the external control terminal. If connecting an inductive load (relay or coil) to the
output of the external control terminal, insert a diode or use a relay with a surge absorbing element so
that counter-electromotive force is not generated.
Figure 4-3 RF power supply INTERFACE connector pin assignments
3
16
RF ON command※
10V
8
7
+
-
Pf Monitor
Ext Control Device
20
1
14
EXT Interlock Input※
2
15
RESET※
5
18
ALARM
4
17
RF ON Answer
6
19
ARC
POWER SET
21
9
Pr Monitor
22
10
VDC Monitor
23
11
VPP Monitor
24
Inside power supply
25V 100mA max
25V 100mA max
25V 100mA max
(NO)
(NO)
(NO)
+
-
+
-
+
-
12
25
Interlock Response
(NO)
25V 100mA max