Indication
Alarm Name
Status
ov
(ov)
Overvoltage in the main
circuit
An overvoltage has been detected.
Cause
Measures
Reference
Occurrence of power outage
Check the power wiring.
3.6.1
The motor is ground fault.
Contact to ULVAC service center.
End of
Document
Extremely high power supply
voltage
Check the supply voltage.
➡
Reduce the voltage to the power supply specifications
of this machine.
7.1
Inverter failure
Contact to ULVAC service center.
End of
Document
Indication
Alarm Name
Status
oH
(oH)
Inverter overheating
Inverter overheating was detected.
Cause
Measures
Reference
Excessive ambient
temperature
Reduce the ambient temperature.
3.1.3
Ventilation fan failure
Contact to ULVAC service center.
End of
Document
Insufficient cooling water flow
rate
Check the cooling water and increase the amount of
supply.
3.5.2
Insufficient differential pressure at the cooling water
inlet/outlet
➡
Increase the supply pressure.
3.5.2
The cooling water piping is clogged, or impurities are
mixed in the cooling water.
➡
Clean the piping.
3.5.2
Leakage from the cooling water piping
➡
If it is in this machine, Contact to ULVAC service
center.
End of
Document
Содержание MS120A
Страница 2: ......
Страница 10: ......
Страница 14: ......
Страница 47: ...33 YO20 0938 DI 001 00 Figure 16 I O block diagram for remote control wiring...
Страница 65: ...51 YO20 0938 DI 001 00 7 2 External Dimensions Figure 17 External dimensions of MS120A MS120A...
Страница 67: ...53 YO20 0938 DI 001 00...
Страница 68: ...54 YO20 0938 DI 001 00...
Страница 69: ...55 YO20 0938 DI 001 00...