TROUBLESHOOTING CHART
ITEM
PROBLEMS
POSSIBLE SOLUTIONS
1
Main burner will not ignite. Blower is operating;
but gas is not present at the burner.
A. Check the Blower air pressure Switch by temporarily
disconnecting the two (2)
ORANGE
air switch wires and
connecting them together. If the
IGNITOR
sparks when these
wires are connected, the air pressure switch is defective and it
will have to be replaced.
B. Check the following components and replace if found to be
defective: Gas Control Valve
Hi-Limit Switch
Transformer
2
Electrical power is present at the fryer, but the
Blower is not operating.
A. Blower may have over-heated and shut off on thermal overload.
If this situation did occur, it will correct itself when the motor
cools (10-20 minutes). If this overheating problem persists, re-
place the blower.
3
Excessive time is required to raise the shortening
to cooking temperature. Temperature recovery is
slow and main burner flames are small and appear
to be lethargic.
A. Ensure that the MANUAL GAS VALVE is completely open.
B. Check for an obstruction in the gas line.
C. Check for an obstruction in the flue pipe.
D. Check that the ORFICE PLUG has the correct drill size opening
as indicated on the operational requirements on the chart
shown on page 7.
E. Check for damaged BLOWER fins.
F. Use a standard water-type U-gauge Manometoer to check the
pressure at the gas control valve pressure tap. Proper gas
pressure is indicated on the perational requirements chart
shown on page 6.
NOTE:
If necessary remove the Pressure Regulator Adjustment
Cover and adjust this control to the proper pressure.
(Turn adjusting screw
CLOCK-WISE
to increase gas
pressure to the burner and
COUNTER CLOCKWISE
to decrease gas pressure. Replace adjustment cover.)
4
Shortening temperature is too high and breaks
down quickly.
A. Check the gas pressure as described above.
B. Check calibration of the Electronic Thermostat with an
ACCURATE
digital thermometer.
5
The filter pump motor fails to operate when the
Vat Shortening Return / Topside Shortening Lever
is placed in the
OPEN
position.
A. Insure the filter pump micro-switch is good, then check the
manual reset button on the filter pump motor.
B. If the filter pump motor fails to operate after the reset button
has been depressed, repair or replace the motor.
6
Decreased shortening flow rate while filtering.
A. Check for excessive sediment on the filter screen, standpipe
suction fitting or in filter tub.
7
Pump/Motor operates but does not pump shore-
tening.
A. Check for congealed shortening in the shortening system.
B. Check for loose Standpipe / Suction Line Coupler connection.
Page 24 of 61
Содержание PAR-3-HE
Страница 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Страница 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Страница 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Страница 18: ...30A135 INITIAL START UP Page 14 of 61...
Страница 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Страница 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Страница 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Страница 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Страница 31: ...30A135 CLEANING Page 27 of 62...
Страница 36: ...30A135 FRYER OPERATION Page 32 of 61...
Страница 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Страница 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Страница 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Страница 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Страница 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Страница 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Страница 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Страница 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Страница 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...