30A135
e.
EXIT MELT BUTTON -
When this button is momentarily depressed, the melt cycle timing module in the
DTMR’s Default-to-Melt circuit will switch to the
FULL-ON
position allowing the Electronic Thermostat to
heat shortening to its
PRE-SET
temperature.
D. DTMR OPERATION -
Prior to operating the Model PAR-3-HE Gas Fryer,
ENSURE
the Filter Tub Assembly is prop-
erly installed and
DOCKED
to the fryer’s Bulkhead socket and the Temperature Control Access Door is closed, the
fryer vat is filled with shortening to the middle of the
“E”
in the word
LEVEL
of the shortening level mark on the rear
wall of the vat; then:
1. Turn the Toggle ON/OFF Power Switch to the
OFF
Position.
2. Turn the
MANUAL
gas valve to the
OFF
position and wait
FIVE
(5) minutes for any accumulated gas to disperse.
3.
ENSURE
the
MAIN
gas shut-off valve is in the
ON
posi-
tion, and that the
EXHAUST FAN
is
ON.
4.
Turn the
MANUAL
gas valve to the
ON
position.
5
.
Perform the following steps, in the order listed:
ITEM
ACTION
DTMR CONDITION
1
ENSURE
the drain valve is in the CLOSED
UP
position and that shortening is at the proper
level; then turn the Toggle ON/OFF switch to the
ON
position.
A.
AMBER
power lamp will
LIGHT
.
B.
BLUE READY
TO START lamp will
LIGHT.
CAUTION: PRIOR TO PROCEEDING TO STEP 2 VISUALLY CHECK THAT THE HEAT ELEMENT IS
COVERED WITH AT LEAST 2” (51 mm) OF SHORTENING.
2
Depress, then release the momentary
START
button.
A.
RED STARTED
lamp and
AMBER MELT MODE
lamp will light.
B.
BLUE READY TO START
lamp will turn
OFF.
C. The
MELT CYCLE TIMING MODULE
in the Default-To-Melt electrical circuit
will begin cycling the fryer heat mechanism
ON
for twelve (12) seconds and
OFF
for 28 seconds to safely heat the shortening.
CAUTION: PRIOR TO PROCEEDING TO STEP 3, VISUALLY CHECK THAT THE SHORTENING COMPLETELY COVERS
THE HEAT MECHANISM.
3
Depress, then release the momentary
EXIT
MELT
button.
A.
AMBER MELT MODE
lamp will turn
OFF, RED STARTED
lamp will
remain lit.
B. The
Melt Cycle Timing Module
in the Default-To-Melt circuit will switch
to the
FULL ON
position allowing the Electronic Thermostat to heat
shortening to its pre-set temperature.
4
When the fryer’s pre-set temperature has
been reached, initiate a cook cycle.
Page 34 of 61
Содержание PAR-3-HE
Страница 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Страница 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Страница 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Страница 18: ...30A135 INITIAL START UP Page 14 of 61...
Страница 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Страница 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Страница 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Страница 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Страница 31: ...30A135 CLEANING Page 27 of 62...
Страница 36: ...30A135 FRYER OPERATION Page 32 of 61...
Страница 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Страница 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Страница 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Страница 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Страница 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Страница 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Страница 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Страница 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Страница 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...