30A135
MODEL PAR-3-HE GAS FRYER
F. OPERATING CONTROLS:
The “basic” PAR-3-HE gas fryer is equipped with an Electronic Thermostat and Default-to-Manual-Restart (DTMR) control;
However customers may request the fryer be equipped with an “optional” Ultrastat Cooking Computer, such as an Ultrastat 11,21
or 25 Cooking Computer shown below. When applicable, operating instructions for the Ultrastat Cooking Computer will be
provided with the fryer. Operating controls on the Model PAR-3-HE gas fryer include the Toggle
ON/OFF
Switch,
AMBER
Power
Indicator Lamp,
RED
Burner Indicator Lamp, and the applicable Temperature Controller. These controls are mounted on the
Temperature Control Access Panel; and the Electronic Thermostat and other fryer controls are located behind the access door. The
main drain valve and shortening return levers are located behind the Service Access Panel. These controls were identifi ed in the
illustrations shown on the previous page.
G. AUTOMATIC SAFETY FEATURES:
1. High limit thermostat to shut off gas to the main burners by opening a solenoid-actuated safety valve in the combination gas
control valve.
2. Combination gas control valve which includes a built-in pressure regulator and manual valve.
3. Sensing circuit within the spark ignitor module to turn gas to the fryer
OFF
if a burner
FLAME OUT
occurs.
4. A Drain Valve Safety Switch and a Default-to-Off circuit in the Default-to-Manual-Restart (DTMR) Control that will
DIS-
ABLE
the fryer each time the drain valve is
OPENED
.
5. An
AIR PRESSURE
switch to open the electrical circuit to the spark ignitor and gas valve which will turn the gas to the fryer
OFF
in the event the blower motor fails.
H. RATING PLATE:
Information on this plate includes the model and serial number; BTU/HR input rating of the burners; gas manifold pressure in
inches W.C. ; minimum inlet gas required, orifi ce size; and type of gas. This data is essential for proper identifi cation when comm-
nicating with ULTRAFRYER SYSTEMS or requesting special parts or information. The rating plate is located on the inside of the
Service Access door.
THE FRYER MUST BE CONNECTED ONLY TO THE TYPE OF GAS IDENTIFIED ON THIS RATING PLATE!
Page 5 of 61
Содержание PAR-3-HE
Страница 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Страница 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Страница 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Страница 18: ...30A135 INITIAL START UP Page 14 of 61...
Страница 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Страница 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Страница 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Страница 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Страница 31: ...30A135 CLEANING Page 27 of 62...
Страница 36: ...30A135 FRYER OPERATION Page 32 of 61...
Страница 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Страница 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Страница 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Страница 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Страница 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Страница 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Страница 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Страница 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Страница 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...