PREVENTIVE MAINTENANCE:
Minimal maintenance is required on Model PAR-3-HE gas fryer because of its design and
the materials used in the manufacturing process. However, some preventive maintenance and inspection must be performed
periodically to prevent break downs which could curtail food sales. Any preventive maintenance or inspection should be ac-
complished with
CAUTION
while the fryer is in operation since
HOT
liquid shortening could cause severe burns. If service
or repair is required, all gas and electric power
MUST BE TURNED OFF PRIOR TO
performing that service or repair.
PREVENTIVE MAINTENANCE SCHEDULE
INSPECTION ITEM
INSPECTION
PRIORITY
INSPECTION
DESCRIPTION
Grease Filters
DAILY
Clean grease filters in the exhaust
vent hood each evening and allow
them to dry overnight.
Filter Tub
DAILY
Thoroughly clean the filter tub
assembly prior to leaving the store at
closing
Drain Valve & Shortening
Return Levers
WEEKLY
Determine that all levers are securely
attached and that they can be easily
opened and closed.
Temperature Sensing Probes
WEEKLY
During Boil-Out of the fryer, inspect
the temperature and high limit sens-
ing probes for any visual damage.
WARNING: CRUMBS AND SLUDGE LEFT IN THE FILTER TUB OVERNIGHT ARE A FIRE HAZARD
B TROUBLESHOOTING
I. GENERAL:
The problems and possible solutions listed in the troubleshooting chart below are typical problems that are frequently
encountered.
ONLY
qualified repairmen are to use the troubleshooting chart to repair this fryer. In the event a main burner mal
function occurs, perform the following checks
PRIOR
to contacting a repairman:
a. Ensure Gas Valves are in their proper position.
b. Check that the fryer electrical plug is connected to an electrical receptacle.
c. Ensure the applicable Circuit Breaker is in the
ON
position and that the fryer ON/OFF switch is in the
ON
position.
d. Ensure the applicable fryer control has been placed in the
FULL ON
mode.
e. Ensure the gas supply line quick-disconnect coupling is
SEATED
on the gas manifold fitting.
f.
Determine that the blower is operating.
C TROUBLESHOOTING CHART:
Should a problem occur that cannot be corrected after performing the above CHECKS, contact
an authorized repairman and/or Ultrafryer Systems Systems Customer Service 1-800-525-8130 and provide the information
acquired while performing these checks.
CAUTION: ENSURE REPAIRMEN ARE ADVISED THAT FRYER RESTRAINTS MUST BE DISCONNECTED/CONNECTED.
IF A FRYER IS TO BE MOVED DURING MAINTENANCE OR REPAIR, AND THAT ELECTRICAL POWER AND
GAS MUST BE TURNED OFF PRIOR TO PERFORMING ANY MAINTENANCE OR REPAIR.
Page 23 of 61
Содержание PAR-3-HE
Страница 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Страница 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Страница 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Страница 18: ...30A135 INITIAL START UP Page 14 of 61...
Страница 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Страница 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Страница 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Страница 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Страница 31: ...30A135 CLEANING Page 27 of 62...
Страница 36: ...30A135 FRYER OPERATION Page 32 of 61...
Страница 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Страница 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Страница 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Страница 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Страница 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Страница 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Страница 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Страница 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Страница 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...