INLET GAS LINE REQUIREMENTS
PIPE
LENGTH
PIPE DIAMETERS (inches & (mm equivalents))
Maximum Allowable Flow (Shown in ft
3
/hr (M
3
/hr))
Feet
(Meters)
15
(4.6)
62
(1.7)
170
(4.7)
350
(9.8)
620
(17.4)
960
(26.9)
2,000
(56.0)
3,500
(98.0)
5,400
(151.2)
11,200
(313.6)
30
(9.1)
43
(1.2)
120
(3.4)
245
(6.9)
430
(12.0)
680
(19.0)
1,400
(39.2)
2,450
(68.6)
3,800
(106.4)
7,900
(221.2)
45
(13.7)
35
(1.0)
98
(2.7)
200
(5.6)
355
(9.9)
530
(14.8)
1,150
(32.2)
2,000
(56.0)
3,200
(89.6)
7,900
(182.0)
60
(18.3)
30
(0.8)
84
(2.4)
175
(4.9)
310
(8.7)
480
(13.4)
1,000
(28.0)
1,760
(49.3)
2,700
(75.6)
5,600
(156.8)
75
(22.9)
27
(0.8)
76
(2.1)
155
(4.3)
275
(7.7)
430
(12.0)
890
(24.9)
1,560
(43.7)
2,450
(68.6)
5,000
(140.0)
90
(27.4)
25
(0.7)
70
(2.0)
145
(4.1)
250
(7.0)
395
(11.1)
810
(22.7)
1,430
(40.0)
2,260
(63.3)
4,550
(127.4)
105
(32.0)
23
(0.6)
64
(1.8)
132
(3.7)
232
(6.5)
370
(10.4)
(750
(21.0)
1,300
(36.4)
2,100
(58.8)
4,200
(117.6)
120
(36.6)
21
(0.6)
60
(1.7)
125
(3.5)
215
(6.0)
340
(9.5)
700
(19.6)
1,200
(33.6)
1,950
(54.6)
4,000
(112.0)
150
(45.7)
19
(0.5)
54
(1.5)
110
(3.1)
195
(5.5)
310
(8.7)
630
(17.6)
1,080
(30.2)
1,750
(49.0)
3,550
(99.4)
180
(54.9)
17
(0.5)
49
(1.4)
100
(2.8)
175
(4.9)
280
(7.8)
570
(16.0)
960
(26.9)
1,600
(44.8)
3,200
(89.6)
210
(64.0)
16
(0.4)
44
(1.2)
94
(2.6)
165
(4.6)
260
(7.3)
530
(14.8)
890
(24.9)
1,450
(40.6)
3,000
(84.0)
240
(73.2)
15
(0.4)
43
(1.2)
88
(2.5)
155
(4.3)
240
(6.7)
500
(14.0)
840
(23.5)
1,350
(37.8)
2,800
(78.4)
270
(82.3)
14
(0.4)
40
(1.1)
83
(2.3)
145
(4.1)
230
(6.4)
470
(13.2)
780
(21.8)
1,300
(36.4)
2,650
(74.2)
300
(91.4)
14
(0.4)
38
(1.1)
79
(2.2)
138
(3.9)
215
(6.0)
440
(12.3)
750
(21.0)
1,250
(35.0)
2,500
(70.0)
450
(137.2)
11
(0.3)
31
(0.9)
64
(1.8)
112
(3.1)
176
(4.9)
360
(10.1)
630
(17.6)
1,000
(28.0)
2,050
(57.4)
600
(182.9)
10
(0.3)
27
(0.8)
56
(1.6)
97
(2.7)
152
(4.3)
315
(8.8)
530
(14.8)
860
(24.1)
1,750
(49.0)
NOTE:
1) FT3/HR (M3/HR) values may vary due to heating value and specific gravity of gas supplied by local companies.
2) To determine the inlet gas line diameter for the distance between the fryer and main gas regulator, locate the FT3/HR (M3/HR) of gas required for the fryer and
pipe length and read the pipe diameter on the top row. For example: a 18” PAR-3-HE fryer operating on
NATURAL GAS
requires 110 FT3/HR (3.1 M3/HR)
of gas at the fryer’s inlet gas manifold. If the fryer bank is located 60 feet from the building gas regulator, a 1” (25mm) diameter gas line
MUST
be installed
between the manifold and regulator.
1⁄2”
(13 mm)
3⁄4”
(19mm)
1”
(25mm)
11⁄4”
(32mm)
11⁄2”
(38mm)
2”
(51mm)
21⁄2”
(64mm)
3”
(76mm)
4”
(102mm)
I. INLET GAS LINE SIZING:
The Table below is used to calculate the size (diameter) of the inlet gas line from the building regulator to the fryer manifold.
NOTE: The flexible gas line used to connect the gas manifold to the building gas supply line must rated for the BTU/Hr (MJ/Hr) for the Fryer.
For example: the BTU/Hr (MJ/Hr) rating for a PAR-3-HE fryer is 110,000 BTU/Hr (116 MJ/Hr) and therefore would require a 3⁄4” diameter
gas line.
INLET GAS REQUIREMENTS
MODEL PAR-3-HE-3 GAS FRYERS
18” (457)
Butane
Natural
Propane
10.0 (254)
4.0 (102)
10.0 (254)
#36
#16
#32
110,000 (116)
110,000 (116)
110,000 (116)
34 (1.0)
110 (3.1)
44 (1.2)
VAT SIZE
Model PAR-3-HE
IN MM
GAS TYPE
GAS VALVE PRESSURE (WC)
IN MM
ORIFICE HOLE
SIZE
RATING
BTU/HR MJ/HR
INLET GAS FLOW AT
STP
FT
3
/HR M
3
/HR
NUMBER
DESCRIPTION
RATING
BTU/HR (MJ/HR)
24-322
3⁄4” (19mm) Diameter Flexible Gas Line (w/quick connect
couplings) 48” (1219mm) long. Connect-It SSGC75-48-UCQ
225,000 (238)
24-323
1” (25mm) Diameter Flexible Gas Line (w/quick connect
couplings) 48” (1219mm) long. Connect-It SSGC100-48-UCQ
435,000 (459)
24-456
11⁄4” (32mm) Diameter Flexible Gas Line (w/quick connect
couplings) 48” (1219mm) long. Connect-It SSGC125-48-UCQ
875,000 (924)
FLEXIBLE GAS LINES STOCKED BY ULTRAFRYER SYSTEMS
J. INLET GAS REQUIREMENTS
The Flexible Gas Line used to connect the gas manifold to the building gas supply line must be rated for the BTU/Hr (MJ/Hr)
designated for the Fryer. Flexible gas lines and their ratings stocked by Ultrafryer Systems are listed below:
Page 6 of 61
Содержание PAR-3-HE
Страница 5: ...30A135 GENERAL INFORMATION Page 1 of 61...
Страница 11: ...30A135 PRE INSTALLATION Page 7 of 61...
Страница 13: ...30A135 RECEIVING INSTALLING Page 9 of 61...
Страница 18: ...30A135 INITIAL START UP Page 14 of 61...
Страница 22: ...30A135 OPERATING INSTRUCTIONS Page 18 of 61...
Страница 24: ...30A135 MAINTENANCE ELECTRONIC THERMOSTAT CALIBRATION Page 20 of 61...
Страница 26: ...30A135 PREVENTITIVE MAINTENANCE TROUBLESHOOTING Page 22 of 61...
Страница 29: ...30A135 RECOMMENDED SPARE PARTS Page 25 of 61...
Страница 31: ...30A135 CLEANING Page 27 of 62...
Страница 36: ...30A135 FRYER OPERATION Page 32 of 61...
Страница 41: ...30A135 FILTER TUB ASSEMBLY INSTALLATION Page 37 of 61...
Страница 43: ...30A135 FILTERING POLISHING SHORTENING Page 39 of 61...
Страница 48: ...30A135 SHORTENING DISPOSAL BOIL OUT INSTALLATION Page 44 of 61...
Страница 52: ...30A135 TECHNICAL ASSISTANCE ORDERING INFORMATION PARTS IDENTIFICATION Page 48 of 61...
Страница 54: ...30A135 ULTRAFRYER MODEL PAR 3 HE GAS FRYER FRONT VIEW Page 50 of 61 18 PAR 3 HE...
Страница 61: ...30A135 WIRING DIAGRAMS Page 57 of 61...
Страница 63: ...30A135 PAR 3 HE GAS FRYER W COMPUTER Page 59 of 61...
Страница 64: ...30A135 PAR 3 HE GAS FRYER W COMPUTER BASKET LIFT Page 61 of 62...
Страница 65: ...30A135 THIS PAGE INTENTIONALLY LEFT BLANK Page 61 of 61...