Содержание DNCD450EG1WC

Страница 1: ... control system NOTE Installation and service of this dryer requires basic mechanical and electrical skills It is your responsibility to contact a qualified installer to make the electrical connections I TOOLS YOU WILL NEED SLIP JOINT PLIERS _ FLAT BLADE SCREWDRIVER PHILLIPS SCREWDRIVER MATERIALS YOU WILL NEED 4 DIA METAL DUCT 4 RECOMMENDED DUCT CLAMPS 2 OR 4 SPRING CLAMPS 2 4 DIA FLEXIBLE METAL D...

Страница 2: ...ce with the NATIONAL ELECTRI CAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This dryer mnst be connected to an individual branch ei euit protected by the required time delay fllses or circuit breakers A four or three wire single phase 120 240V or 120 208V 60Hz 30 amp circuit is required If the electric supply does lot meet the above specifications then call a licensed electrician GROUNDING INSTR...

Страница 3: ...HAUST LENGTH TABLE Using exhaust longer than specified length will Increase the drying times and the enelgy cost Reduce tile dryer life Accmnulate lint cleating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Tile MAXIMUM ALLOWABLE length of the exhaust system depends upon tile type of duct mnrlb...

Страница 4: ...TRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented above floor level ELBOW HIGHLY RECOMMENDED ELBOW HIGHLY _ RECOMMENDED RECOMMENDED CONFIGURATION TO MINIMIZE EXHAUST BLOCKAGE NOTE ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING STANDARD REAR EXHAUST Vented at floor level FOR STRAIGHT LINE INSTALLATION CONNECT THE DRYER EXHAUST TOTHEEXTE...

Страница 5: ...en dryer cabinet and adjacent walls or other surfaces is 0 in either side 3 in front and rear Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area ...

Страница 6: ...iat blade screwdriver 6 ADDING NEW DUCT FIXING HOLE PORTION A RIGHT OR LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT OR RIGHT SIDE OF CABINET Preassemble 4 e...

Страница 7: ...r hand holding the bottom remove the door from the dryer by lifting it UP and OUT 3 Rotate the door 180 Insert the door on the opposite side of the opening by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in step 1 4 Remove the remaining screws from the side of the opening from which the door was removed With these screws secure each hi...