Chapter 5: Operating Instructions
Alarm-Status
Part No. 24001157
VersaMux-4000 Operation & Installation Guide
Page 5-5
Revision C
Alarm-Status
Selecting the
Alarm-Status
parameter from the Main Menu displays a list of the
active alarms.
provides a list of the alarms their descriptions, and the interfaces they
apply to.
Table 5-1
Alarm Descriptions
Alarm
Description
System
Port
-1
Port
-2
Port
-3
Port
-4
Aggrega
te
POST-Fail
One or more of the Power-On-Self-Tests failed.
X
BIST-Fail
One or more of the Built-In-Self-Tests failed one or more.
X
FTM-Fail
One or more of the Factory-Test-Mode tests failed.
X
Stack-Low
The Operating-System-Stack is low.
X
Hot-Swap
The Hot-Swap mode is enabled.
X
Incompat-HW
The interface card in this slot is incompatible with the
configured mode.
X
X
X
X
X
RefClk_Fail
The Reference-Clock has failed. This failure could be
caused by; no signal present, poor signal present,
reference signal at the wrong rate.
X
SystFPGA
The System FPGA is not programmed.
X
TxAggrFPGA
The Tx-Aggregate FPGA is not programmed.
X
RxAggrFPGA
The Rx-Aggregate FPGA is not programmed.
X
Insuff-BW
The sum of the individual port bandwidths exceeds the
available aggregate bandwidth.
X
LOF
The aggregate is in a Loss-Of-Frame condition.
X
PLL-Lock
The interface card PLL is not locked to the reference.
X
X
X
X
X
Sync-Loss
The interface card receiver is not in sync.
X
X
X
X
X
BERT-Active
The active BERT is affecting port or aggregate user traffic.
X
FIFO-Err
The interface card FIFO has overflowed or has an under-
run condition.
X
X
X
X
X