Chapter 6: Diagnostics
Diagnostics Menu
Part No. 24001157
VersaMux-4000 Operation & Installation Guide
Page 6-17
Revision C
Test
On power-up, the VersaMux-4000 performs a series of Power-On Self Tests (POST)
as described in
. In addition, you can run additional test by selecting
Test
from the
Diagnostics
menu. This accesses a sub-menu with the following items:
•
Test-Status
- Selecting this parameter provides you with the
following information about the current test:
•
Test-State (Active or Idle)
•
Test-Mode
•
Tests-Performed
•
Tests-Passed
•
Tests-Failed
•
Test-Results
- Selecting this parameter accesses a sub-menu with the
following options:
•
Errors-Only –
Selecting this option displays a list of the failed
test(s) from the most recent “Start-Test.”
•
All-Results –
Selecting this option displays a list of every test
result from the most recent “Start-Test.”.
•
Start-Test
- Selecting this parameter displays the following sub-menu
(note that you need to confirm the Start-Test selection in the terminal
interface to enter the sub-menu selection mode):
•
No
- Selecting this option exits the Start-Test option without
initiating any tests.
•
BIST
- Selecting this option commands the VersaMux-4000 to run
the Built-In Self Tests as described in
.
•
Factory
- Selecting this option runs an extensive series of tests
but produces no end-user information. This option is intended for
DNE factory and field service specialists only.
•
Stop-Test
- Selecting this parameter accesses the following sub-menu
(note that you need to confirm the Stop-Test selection in the terminal
interface to enter the sub-menu selection mode):
•
No
- Selecting this option exits the stop-test selection mode and
allows the current test to continue uninterrupted.
•
Yes