Chapter 7: Maintenance
Software Upgrade Procedure
Part No. 24001157
VersaMux-4000 Operation & Installation Guide
Page 7-19
Revision C
15. Go to the
Transfer
“drop-down” menu in the HyperTerminal window
and select
Send Text File...
(Note that you need to set the
Files of
type:
field in the
Send Text File
dialog box to
All files (*.*)
, as
shown in
, to access the mcs files.)
Browse to location of the FPGA software upgrade file and select the
appropriate “mcs” file as follows (note that the file name may be
slightly different depending on the revision/version). For example:
The file for selection
0
(zero) is sys_fpga_0406.mcs
This is the system FPGA code.
The file for selection
1
is mux_0204.mcs
This is the Mux FPGA code.
The file for selection
2
is demux_0406.mcs
This is the DeMux FPGA code.
16. When the transfer is complete, select the
Store FPGA Checksum
option (enter a
7
) from the
SOFTWARE UPGRADE UTILITY
menu to
store the FPGA code as shown in
. The system prompts
you (
Which FPGA Program?
) to select the FPGA to store.
NOTE:
This step is necessary in order to pass the POST test.
17. Enter a
0
(zero),
1
, or
2
corresponding to the FPGA that you are
upgrading. Enter a
y
at the prompt to confirm.
Figure 7-16
Storing the FPGA Program for the DeMux FPGA (option 2)