SPECIFICATIONS
ULINE PART NO.
MFG. PART NO.
LENGTH
HEIGHT
WIDTH
WEIGHT
STAPLE
CAPACITY
H-3532
DS-3219
12.6" (320 mm)
8.86" (225 mm)
4.5" (115 mm)
5.45 lbs. (2.45 kg)
120
H-3534
DS-3522
12.6" (320 mm)
8.86" (225 mm)
4.5" (115 mm)
5.45 lbs. (2.45 kg)
120
STAPLER
ULINE PART NO.
LEG LENGTH
STAPLE SERIES
WIRE SIZE
CROWN WIDTH
FASTENER RANGE
H-3532
S-18710
5/8" (24 mm)
B58C
.074 x 0.37"
(1.88 x .94 mm)
1⁄"
(32 mm)
5/8 - 3/4"
(15-19 mm)
S-18711
3/4" (29 mm)
B34C
.074 x 0.37"
(1.88 x .94 mm)
1⁄"
(32 mm)
5/8 - 3/4"
(15-19 mm)
H-3534
S-18715
5/8" (24 mm)
SW7437
.074 x 0.37"
(1.88 x .94 mm)
1⁄"
(35 mm)
5/8 - 3/4"
(15-19mm)
S-18716
3/4" (29 mm)
SW7437
.074 x 0.37”
(1.88 x .94 mm)
1⁄"
(35 mm)
5/8 - 3/4”
(15-19 mm)
STAPLER AIR FITTING
This stapler must use a male free-flow connector plug,
1/4" (11 mm) N.P.T. The minimum inside diameter should
be .300" (5 mm). Fitting must be capable of discharging
stapler air pressure when disconnected from the air
supply.
OPERATING PRESSURE
The operating pressure of the stapler is 70 to 100 psi
(5 to 7 kg/cm2). Select the operating pressure within this
range for best fastener performance.
CAUTION: Do not exceed the recommended
operating pressure.
AIR CONSUMPTION
Model H-3532/H-3534 requires 4.0 cubic feet per minute
(.113 cubic meters) of free air to operate at the rate
of 100 fasteners per minute, at 80 psi (5.66 kg/cm2).
Take the actual rate at which the stapler will be run to
determine the amount of air required. For instance, if
your fastener usage averages 50 fasteners per minute,
you need 50% of the stapler's cfm of free air which is
required for running at 100 fasteners per minute.
STAPLER SPECIFICATIONS
FASTENER SPECIFICATIONS
PARTS/STAPLE CHART
MODEL
H-3532/H-3534
H-3534
CLINCHERS
STANDARD/FLAT
DEEP
A01900601 (L.H.)
A01900501 (R.H.)
A01200601 (R.H.)
A01200601 (L.H.)
SPACERS
A02300801
A02300801
—
—
STAPLE
LENGTHS
5/8" (16 mm)
3/4" (19 mm)
3/4" (19 mm)
7/8" (22 mm)
DIAL
POSITION