IG. 51
Connect the
Lat Bar (#16)
to the
Lat Cable (#11)
using one
trap Bracket (#74), one Shoulder Bolt 3/8 X 3/4 (#70) and one Nylon
nsert Lock Nut 5/16-16 (#9). Use the Supplied 3/16” Hex Key (#79) and
1/2” combination wrench to fasten this assembly properly.
Note:
Refer to
Fig. A
on page 16 for further illustration of this
assembly.
15
20
25
30
35
45
55
65
75
85
95
105
115
125
140
155
170
185
200
Adjustment for:
Adjustable Stopper (#83)
1. Loosen both Regular Hex Nuts 1/2-13 (#84)
2. Adjust the
Adjustable Stopper (#83)
to make contac
with the
Adjustable Double Pulley Brkt. (#40)
3. Re-tighten both Regular Hex Nuts 1/2-13 (#84) t
complete the adjustment.
Note:
Be sure that the
Adjustable Double Pulle
Brkt. (#40)
is always resting on the
Adjustabl
Stopper (#83)
.
Cable Adjustment for:
Adjustable Double Pulley Brkt. (#40)
1. Remove the hardware from the Nylon Pulley 4 1/2 Rd
(#26) located at one of the four holes on the
Adjustabl
Double Pulley Brkt. (#40)
.
2. By interchanging the Nylon Pulley 4 1/2 Rd. (#26) to
the next adjustment hole, this will make a one inch ca
ble adjustment.
3. Re-tighten the hardware for Nylon Pulley 4 1/2 Rd
(#26) to complete the cable adjustment.
FIG. 52
To attach the Decal Weight Numbers (#86) we recommen
using a piece of masking tape as a guide to vertically center the Deca
Weight Numbers (#86), as shown above.
Note:
Attach the Decal Weight Numbers (#86) in the numerical se
quence as illustrated above.
CFM-500 CABLE ADJUSTMENTS DIAGRAM
Cable Adjustment for:
Adjustable Pulley Bracket (#42)
1. Loosen the bottom Regular Hex Nut (#84)
2. Adjust the top Nylon Insert Jam Lock Nut (#58) to give
the cable proper tension.
3. Re-tighten the bottom Regular Hex Nut (#84) t
complete the cable adjustment.
CFM-500 Compact Frontal Machin
15