IMPORTANT OPTION
•
If the door closes against a fixed door stop that is door frame mounted, the
CLOSED STOP
does
NOT
have to be adjusted to meet the stop-point screw. The step is then optional.
•
The open door stop setting is optional. A "
SOFT STOP"
is sometimes preferred depending upon
the application, particularly if heavy manual use is anticipated. The Soft Stop is simply a method
of programming the door for the open position by means of a temporary stop method; such has
holding your foot at the desired location during programming. To use the Soft Stop method,
perform the following:
o
Press the automatic setup button (SW1 - as shown on page 14), to allow the
start of the setup process
o
Position your foot on the ground at the desired full open door position.
Allow the door to open and hit your foot during the first opening cycle during
setup - you can then remove your foot from that position.
o
Allow the setup to complete itself thereafter
o
The door will open automatically thereafter to that position. When the door is
pushed further than the soft stop location it will return to the programmed
point automatically.
o
Do not use the soft stop method if there is anything behind the open door that
the door could be repeatedly pushed into from manual openings - such as a
glass wall.
Содержание SW10
Страница 11: ...920 1020 12 11 PUSH ARM ...
Страница 27: ...920 1020 12 27 SETUP BUTTON FLASHING RED LED ...
Страница 33: ...920 1020 12 33 APPENDIX WIRING DIAGRAMS SIMULTANEOUS PAIRS ...
Страница 35: ...920 1020 12 35 APPENDIX WIRING DIAGRAMS ELECTRIC LOCK APPLICATION ...
Страница 36: ...920 1020 12 36 APPENDIX WIRING DIAGRAMS SW10 PAIR WITH BEA PARALLAX SYSTEM ...
Страница 37: ...920 1020 12 37 APPENDIX WIRING DIAGRAMS SW10 Single Pair WIth BEA LZR Microscan Sensors ...
Страница 38: ...920 1020 12 38 APPENDIX WIRING DIAGRAMS SW10 Single With Push Plates Torpedo Sensors For Secondary Activation ...
Страница 42: ...920 1020 12 42 APPENDIX TUCKER LOGO ...