920.1020.12
23
STEP 10:
120 VOLT AC ELECTRICAL CONNECTION
•
Connect the main power to the Black / White / Green connector on the back-plate.
o
Main power supply: 120 VAC, 15A, Single Phase, 60 Hz. circuit
o
Attach the incoming 120 volt AC line wires to the wiring provided in the header – as
shown below.
•
DO NOT TURN POWER ON until all remaining wiring has been completed.
BLACK: 115 VAC Power
WHITE: Neutral
GREEN: Ground
WARNING:
Ensure all incoming electrical power is shut off before proceeding
with any wiring to SW10/19. Failure to do so may result in damage
to equipment or personal harm.