Rotating the rotary flange to 17° position
1
M4 screws for clamping
rotary flange (4 x)
2
Scale for 0° and 17° position
Fig. 112307
1. Loosen 4 x M4 screws, but do not completely unscrew
them. There must be no gap between the two parts of the
rotary flange to prevent dirt entering the optical compartment
of the PFO.
2. Turn the upper part of the joint counter-clockwise to 17°.
3. Retighten the 4 x M4 screws.
2
‐
28
Installation
2022-03
12-29-01-A1-CRen