Wavelength spectrums do not match
Focusing optics are designed for defined wavelength spectrums.
If a focusing optics is operated with a different wavelength than
specified, unforeseen reflections and transmissions to optical
components may occur. The housing of the focusing optics can
heat up strongly as a result (> 300 °C). The following dangers
result from this:
■
Fire hazard:
Materials in the environment of the focusing
optics can catch fire.
■
Risk of burns:
People who work with the focusing optics
may suffer burns.
■
Risks from escape of laser radiation:
People in the envi-
ronment of the focusing optics may be injured by escaping
laser radiation. Skin burns and loss of eyesight are possible.
■
Risks of laser radiation in eyepiece and stereo micro-
scope:
People who look into the eyepiece or the stereomi-
croscope during the processing operation can lose their eye-
sight.
Focusing optics is not designed for the rated power of the
laser device
A focusing optics will be damaged if it is operated with a higher
average power than that which is specified. The housing of the
focusing optics can heat up strongly (> 300° C). The following
dangers result from this:
■
Fire hazard:
Materials in the environment of the focusing
optics can catch fire.
■
Risk of burns:
People who work with the focusing optics
may suffer burns.
■
Risks from escape of laser radiation:
People in the envi-
ronment of the focusing optics may be injured by escaping
laser radiation. Skin burns and loss of eyesight are possible.
Laser light cable or focusing optics are not from TRUMPF
When the laser device is combined with components that are
not from TRUMPF, the integrator or the operator must draw up
a risk assessment for the combined machine. This risk assess-
ment must include risks that could occur through the combina-
tion of the individual components.
Information required to assess the safety of a combination
Information on the numerical aperture and on the wavelength
spectrum is available either in the user's compartment or on the
incoupling optics.
12-29-01-A1-CRen
2022-03
Installation
2
‐
19
Focusing optics is not
designed for laser device
Rated power of the laser
device is too high
Unknown risks
Information on the laser
device
Содержание KF023
Страница 1: ...Operator s manual Programmable focusing optics PFO 33 KF023...
Страница 2: ......
Страница 3: ...Operator s manual Programmable focusing optics PFO 33 KF023 Original operator s manual Edition 2022 03...
Страница 6: ...II Good to know 2022 03 12 29 01 A1 CRen...
Страница 12: ...0 6 Table of contents 2022 03 12 29 01 A1 CRen...
Страница 81: ...Protective glass monitoring active Fig 112272 12 29 01 A1 CRen 2022 03 Installation 2 43...
Страница 90: ...2 52 Ambient conditions 2022 03 12 29 01 A1 CRen...
Страница 112: ...3 22 Software 2022 03 12 29 01 A1 CRen...
Страница 142: ...4 30 Adjusting the observation optics 2022 03 12 29 01 A1 CRen...
Страница 170: ...5 28 Cooling water 2022 03 12 29 01 A1 CRen...
Страница 176: ...6 6 Informing the service department 2022 03 12 29 01 A1 CRen...