44
Figure 26: View of control panel with lid open, revealing bottom of circuit board.
•
Using a pair of pliers or flat blade screwdriver, the fuse can be removed and inspected.
On newer boards this is a 6.25 amp slow blow fuse. DO NOT use 8A fuses on the circuit
board, as this can lead to excessive heat and board damage.
•
Replace the lid and screws.
•
Connect to power and test. If fuse blows, consult troubleshooting section at the end of
this manual.
To change older style front circuit board mounted fuses:
•
Disconnect control panel power, and disconnect control panel from cutter head.
•
Locate the DB15 connector at the back of the control panel. There are two jack screws
holding this connector in place. Loosen and remove them.
•
Remove the panel screws located around the lower perimeter of the control panel.
•
Open the lid of the control panel. The lid may need to be propped up on it side next to
the controller lower housing.
•
There are four wires from the main wiring harness connecting to the circuit board. They
are red, black, white and purple. Loosen the connections for these wires at the board
terminal block, and pull the wires free.
•
There are four screws securing the circuit board to the lid of the control panel. Locate
them and loosen them. Be careful when removing them that the circuit board does not
fall out.
Fuse
located
here