37
•
(2) Plastic Spacers
•
(1) Trip Lever
•
(5) 6-32 set screws
•
(2) connection wires with spade connectors
•
(1) section of heat shrink tubing for the DB-15 Connection
•
(2) zip ties
•
Disconnect machine from power and allow to cool to prevent contact with hot
machine parts.
•
Disconnect air supply to prevent unwanted machine movement
•
Remove guide plate by loosening side plate bolts. Most machines will have four of
these bolts.
•
Stand machine up on outfeed side.
•
Remove jack screws and nuts from DB-15 connector.
•
Cut off zip tie and heat shrunk insulator from connector - be careful not to cut wires!
•
Solder supplied wires to pins 5 and 12 of connector, taking care not to solder bridge any
connections.
•
Re-install heat shrink tubing. Heat the top portion first (closest to connector) and secure
with zip tie. Heat shrink lower part and trim.
•
Re-install DB-15 connector in back plate and secure with jack screws and nuts.
•
Re-orient the machine so it is sitting in its normal configuration with bottom plate down.
Looking at the infeed side, through the hole where the guide plate was, two small 6-32
threaded holes will be visible on the right inside plate of the machine. These are the
holes for the 6-32 bolts that will hold the micro switch on the right-side plate. The switch
should be installed with switch lever facing up and tip pointing to the front of the
machine.
•
Install supplied wires to bottom 2 spade lugs of trip switch.
•
Locate the holes for the ¼” pivot shaft
(figure 23). These holes may need to be reamed
to clean out residue or paint. Verify fit before attempting next step.