![TRC 1000 4.5 Hot cutter Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/trc/1000-4-5-hot-cutter/1000-4-5-hot-cutter_service-manual_1154721050.webp)
50
3.
Blown circuit board
fuse
4.
Bad control cable
or connections
5.
Blown FET on driver
board
6.
Bad Motor
screws are
tightened. See
Section
“
Drive Belt
Adjustment
”
for
instructions.
2.
Remove side cover
of pulleys to check
belt is properly fed
over pulleys.
3.
See section
“
Replacing Circuit
board fuse for Drive
Rollers
”
4.
Check cable for
damage and
continuity with a
multimeter.
5.
Contact TRC
Industries for repair
6.
Refer to
“
Drive
Motor
Replacement
”
Section
Hot knife does not get hot
1.
Heater element
bad
2.
Faulty terminal
block connections
3.
Bad thermostat
1.
Check heater
element with
multimeter for
continuity and
resistance
2.
Check terminal
block wire
connections to
make sure they are
solidly connected
3.
Replace thermostat
Knife does not jog or move
1.
Gummed up shafts
or linear bushing
2.
No air pressure to
knife air cylinder
3.
Bad air cylinder
4.
Air valve needs
adjusted
5.
Bad triac or driver
on circuit board
6.
Blown fuse on circuit
board
1.
Use wire brush and
solvent to clean
linear shaft. Use
sewing machine oil
or similar to re-
lubricate busing
and shaft
2.
Check air
connections for
leaks, and regulator
for correct pressure
3.
Replace air cylinder
4.
Refer to
“
Adjusting
the Air Valve
”
section for correct
Содержание 1000 4.5 Hot cutter
Страница 1: ...Service Manual for 1000 Series Strip cutters Rev 1 1 6 6 22 ...
Страница 53: ......
Страница 54: ......
Страница 55: ......
Страница 56: ......
Страница 57: ......
Страница 58: ......
Страница 59: ......
Страница 66: ...Drive Transistor Test ...