36
Figure 22: Correct heater element installation. Note the heater element wires do not make contact with the side
plate of the machine. If the wires are allowed to contact the side plate, the insulation will rub off and cause a short.
This short will damage cause serious damage to control panel!
•
Reconnect Air Hoses and check for proper knife operation.
•
Test Unit to for proper heating.
•
Replace Guard Plate before operating machine.
Integrated Cutoff Switch Installation Instructions
The Integrated Cutoff Switch is designed to stop the machine when material supply is
exhausted. This feature can be purchased on any new TRC 1000 series machine, or added on
to any existing 1000 series machine.
The add on kit includes:
•
(1) micro switch
•
(2) mounting screws
•
(1) 1/4" pivot rod
•
(1) 3/16" trip rod
•
(2) side arms