8
Installation (for qualified installers only)
© Travis Industries
9/17/2020 - 1536
DVL EG GSR2
Top Convection Deflector
Install the top convection deflector as
shown to the right.
The deflector is shipped on top of the
insert. The screws are shipped inside
the owner's pack.
Fireplace Requirements
Insert must be placed within a code-conforming masonry fireplace or tested and listed factory-built
(metal) wood-burning fireplace. Repair any fireplace damage prior to installation.
Because the insert uses a circulation blower, clean the fireplace, smoke shelf, and chimney prior to
installation.
This heater may be placed in a bedroom. Please be aware of the large amount of heat this appliance
produces when determining a location.
Fireplace
Sizing
1-Piece Panel
1-Piece Panel w/
Trim
Minimum
Height
24-7/8” (632mm)
23-3/4” (604mm)
Minimum
Front Width
32-1/2” (826mm)
31-1/2” (800mm)
Minimum
Rear Width
20” (508mm)
20” (508mm)
Minimum
Depth
15-3/4” (400mm)
or
16-1/4” (413mm)
w/ Arched Faces
14-1/2” (369mm)
or
15” (381mm)
w/ Arched Faces
Hearth
Extension
0” (0mm)
1-1/4” (32mm)
The gas and electrical line should be installed prior to installing
the heater.
For tight fits (under 28”) see the section “Removing the Vent
Connector”
See “Leveling Bolts” for details on leveling the heater.
h
Attach the “This fireplace has been altered…” plate to the fireplace (use two screws or another
suitable method). You may wish to place it in a location where it will be covered by the surround
panels.
(
4) A