Installation (for qualified installers only)
11
© Travis Industries
9/17/2020 - 1536
DVL EG GSR2
Electrical Requirements
Travis Industries manufactures an “Insert Wiring Kit” for this insert (sku 97200315). This kit allows installers to
wire 120-volt AC power into a fireplace directly to the insert, eliminating the need for an external power cord.
The power cord comes out of the lower front portion of the appliance (stock).
Plug the power cord into a grounded 120 Volt outlet (do not remove the grounding pin).
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the
National Electrical Code, ANSI/NFPA 70
, or the
Canadian Electrical
Code, CSA C22.1
.
Do not route the power over the appliance or near any hot or moving components.
Re-Routing the Power Cord to the Side of the Insert
The power cord is shipped attached to the front right corner of the insert. It may be routed to the side of
the insert. See the directions below for details.
Using the Insert Wiring Kit
See the instructions included with the Insert wiring kit for attaching the kit to the side of the insert.
a
b
c
d
Route wires through the
side mounting hole
Use pliers to reinstall the
strain relief.
(4)
A
A B
att er
ie s
Disconnect the Molex
connector and
remove the power
cord from the front
location.
Reconnect the Molex connector at the
front of the insert. Push the Molex back
under the firebox making sure it will not
make contact with the firebox floor.
Use pliers to remove the
strain relief and carefully
pull the wires through the
mounting hole.
a
b
c
d
(4)
A
A B
att er
ie s
Disconnect the Molex
connector and
remove the power
cord from the front
location.
Reconnect the Molex connector at the
front of the insert. Push the Molex back
under the firebox making sure it will not
make contact with the firebox floor.
Guide hard wire kit
wires and Molex into
the side mounting hole
and attach the hard
wire kit to insert (see kit
instructions for details).
Use pliers to remove the
strain relief and carefully
pull the wires through the
mounting hole.