12
Installation (for qualified installers only)
© Travis Industries
9/17/2020 - 1536
DVL EG GSR2
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture and
draperies.
Minimum
Clearances
k Sidewall to Insert
4" (102mm)
l Side Facing
(non-combustible)
4" (102mm)
m Top Facing*
(non-combustible)
35-1/2" (902mm)
n Mantel* (combustible or
non-combustible)
35-1/2" (902mm)
p Hearth Extension to the
front
0” (0mm)
x Extension onto Hearth
1-Piece Panel w/o Trim
0" (0mm)
1-Piece Panel w/ Trim kit
1-1/4” (32mm)
* Measured from the base of the insert.
NOTE
: the non-combustible top facing must
extend 35-1/2” (902mm) above the base of the
insert or to the bottom of the mantel (whichever is
less).
Mantel Clearances
The maximum mantel depth is 12” (305mm).
NOTE: The combustible area above the facing must not protrude more than 3/4" (20mm) from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
(4 ) A
A
B
att erie
s
Side
Wall
Com
bustib
le or
Non
-Com
bustib
le M
ante
l
Com
busti
ble T
op F
acin
g
Non-
Com
busti
ble
Facin
g
l
k
x
n
m
p
Mantel Height
Above Base of Insert (n)
36"(915mm)
35"(889mm)
34"(864mm)
33"(839mm)
37"+(940mm+)
32"(813mm)
31"(788mm)
0" 1" (26mm)
2" (51mm)
8" (204mm)
7" (178mm)
6" (153mm)
5" (127mm)
4" (102mm)
3" (77mm)
9" (229mm)
10" (254mm)
11" (280mm)
12" (305mm)
Maximum Mantel Depth