28
Finalizing the Installation
© Travis Industries
9/17/2020 - 1536
DVL EG GSR2
9. Check the air shutter following the directions below.
Air Shutter Adjustment
Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be
yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame.
10. Attach the face following the directions included with the face.
11. Adjust the flame to its highest position - the flames should not contact the top of the firebox. Check the flame on low
position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer
for a remedy.
12. Give this manual to the homeowner for future reference and fully explain the operation of this heater.
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are too tall or sooty on the
ends, open the air shutter.
Not Enough Air
If the flames are all blue and
short, close the air shutter.
Too Much Air
(4) A
A B
att er
ies
Front Burner Air Shutter Contro
(RED)
Left = More Air
Right = Less Air
Rear Burner Air Shutter Control
(GOLD)
Left = More Air
Right = Less Air