Installation (for qualified installers only)
17
© Travis Industries
9/17/2020 - 1536
DVL EG GSR2
Vent Configurations
CAUTION:
The “Exhaust Only Re-line” is not covered under the appliance safety standard (ANSI
Z21.88 CSA
2.33
) used in the safety certification of this appliance. The Omni safety certification does not apply to this
installation. Before installing the appliance using this method, contact the Authority Having Jurisdiction to
determine if this installation is acceptable in your area. This type of installation requires a minimum chimney
cross-section of 48 square inches.
Factory Built (Metal) Wood-
Burning Fireplace
Inlet & Exhaust Re-Line
Exhaust Only Re-Line
Recommended Block-Off
Plate (must be non-
combustible - metal /
insulation). Prevents odors
from chimney entering
room.
A block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.
Block-Off Plate
(must be non-combustible -
metal / insulation)
NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.
Masonry Fireplace
Any cracks or
damage inside the
chimney must be
repaired.
Inlet
Exhaust