![Travis Industries 2003 ROF Скачать руководство пользователя страница 31](http://html.mh-extra.com/html/travis-industries/2003-rof/2003-rof_owners-manual_1154158031.webp)
Optional
Equipment
(for qualified installers only)
31
Travis Industries
4030407
100-01146
LP Conversion Instructions
Install the conversion kit prior to installing the gas line to ensure proper gas use.
NOTE
:
Remove all 3 screws in the primary air tube when using LP – see page 25.
1. Disconnect the pilot line compression fitting at the pilot. Hold the pilot bracket still with a pair of
pliers and use a ½” wrench to loosen the compression nut. Carefully remove the end of the pilot
line. The orifice is sitting loosely on the end of the pilot line. If not, give the pilot bracket a light tap
and the orifice should drop right out. Replace the orifice with the LP orifice, the one with N16
markings. It usually has a red mark on it.
2. Remove the two nuts holding the burner orifice bracket. Drop the bracket and orifice down.
Change the Natural gas orifice with the LP orifice, the one with a #37 hole. It usually has a red
mark on it. Remove the 3 screws in the burner primary air tube (see page 25).
3. Remove the plastic cap on the gas type conversion screw on the gas control valve. Unscrew the
conversion screw. Rotate the screw 180 degrees and screw it back into the valve. The end with
LPG markings (the side with the red stripe) is screwed into the valve. Replace the plastic cap.
The red strip on the conversion screw is now visible.
4. Follow the instructions in the manual to make the gas line connection.
At Back, Under Tub.
At Back, Under Tub.
Burner Orifice Location
Pilot Location
Valve Gas Type Conversion
Screw Location
Burner Orifice
Pilot Orifice
Valve Conversion Screw
LP: #37 Drill
LP: LP 16 (usually has a red
mark)
LP: The side marked LPG (usually
has a red stripe)
Natural Gas: 3/16” Drill
Natural Gas: N 26
Natural Gas: The side mark NAT