![Travis Industries 2003 ROF Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/travis-industries/2003-rof/2003-rof_owners-manual_1154158018.webp)
18
Installation
(for qualified installers only)
© Travis Industries
4030407
100-01146
Control Box Connections
For safety reasons, the control box should be located:
•
In a dry location.
•
In a place where the fountain can be viewed during operation of the control box.
•
4’ Above the ground, away from the reach of small children.
•
In plain sight of the fountain, where it is easy accessible in case of emergency.
The control box operates on low voltage. However, electrical codes must be observed in its
installation.
•
Disconnect the electrical supply before installing the control box.
•
Find a suitable location to mount the control box. Attach the mounting base using suitable
fasteners –
NOTE
: the control wire can be run through the back or bottom (using the optional
knock-out) of the mounting base (see the illustration below).
•
Uncoil the 25ft roll of 8-conductor cable. Run the end without the connector block through one of
the holes on the mounting base from the inside. Leave 6” slack for the connector block to connect
to the control box. Install the plastic strain relief over the cable and press it into the mounting
base (this protects the cable). Connect the connector block on the cable to the blcok on the
control box.
•
Attach the control box to the mounting base –
NOTE
: the control box is difficult to remove once it
is installed. Attach the control cover onto the control box.
•
Strip ¼” of the insulation off the wires on the end of the cable. Attach the included spade
connectors to the wires (
NOTE
: the light blue wire is not used). Connect the wires to the terminal
block of on the fountain (see the illustration below). Note the color-coding on the conductors and
the markings on the terminal block.
Control Box
(with cover)
Lig
ht
Wa
ter
Fla
me
Black
Red
White
Yellow
Orange
Brown
Green
Blue
Black
Red
White
Yellow
Orange
Brown
Green
Blue
Remote Control
Terminal Block
Control Box
Mounting Base
Additional knock-out for
“Down-the-wall” wire route.