![Travis Industries 2003 ROF Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/travis-industries/2003-rof/2003-rof_owners-manual_1154158016.webp)
16
Installation
(for qualified installers only)
© Travis Industries
4030407
100-01146
Water Supply Connection
1. Disconnect the electrical supply before proceeding.
2. Purchase adequate length of ¼” polyethylene tubing and the required fittings to connect the
fountain to a suitable cold water supply outlet. The illustration below shows a standard water tap
with female hose thread connected to the fountain. The fittings provided for this application are:
One female hose to ½ MPT fitting and One ½ MPT to ¼” poly tube compression fitting.
3. Remove the compression nut on the fountain float valve (this is the water inlet). Insert the poly
tubing through the compression nut, ferrule, and seat (included with the Ring of Fire - see the
illustration below). Insert the tubing into the water inlet and hand-tighten the compression nut.
Do
not over tighten the compression nut
.
4. Assemble the water tap fittings and connect the free end of the poly tubing to the fittings. Connect
the fittings to the water tap.
5. Turn on the water tap before operating the fountain and check for water leaks. The fountain is
equipped with a low water level sensor. It will not operate without being filled with water. The float
valve located inside the fountain regulates water level in the fountain.
COLD WATER
SUPPLY TAP
FOUNTAIN
FLOAT VALVE
1/2”
Ferrule
Seat
To
Water
Supply
To Ring
of Fire
Water
Inlet
Compression
Nut