Electrical Supply Connection
•
Make sure the household breaker is shut off prior to working on any electrical lines.
•
Electrical supply to the fountain must be properly protected by a ground fault circuit
interrupter (GFCI). All electrical connections must conform to local codes or ANSI/NFPA
70-1987.
•
The fountain electrical supply requirement is 110 Volts, 60 Hz, 3A.
Directions for electrical supply connection:
The Ring of Fire is supplied with a grounded, 3 prong power cord. It can be connected directly to a GFCI
protected 110VAC outdoor receptacle. An outdoor extension power cord may be required.
Hard-wiring the Ring of Fire
1. Disconnect the electrical supply before proceeding.
2. Use a ¼” nut drive and remove the two screws holding the junction box cover.
3. Loosen the cable clamp holding the power cord.
4. Disconnect the connections of the power cord and remove the power cord.
5. Insert the power supply cable through the cable clamp. Tighten the cable clamp.
6. Connect the black hot supply wire to the brown and black wires using a crimp connector or wire
nut.
7. Connect the white neutral supply wire to the two white wires using a crimp connector or wire nut.
8. Loop the bare ground wire under the screw on the side of the metal enclosure and tighten the
screw.
9. Replace the junction box cover and screws.