Gas Line Connection
A manual shutoff valve is required on the gas supply to the fountain. It should be placed upstream of the
flex line (if used) and may be installed behind the access door, inside the fountain enclosure, or on the
gas line serving the fountain.
½” MPT to 3/4” Flare
Minimum 5/8” ID
Gas Line
Gas Inlet Pressure
Standard Input Pressure
Natural Gas
7” W.C. (1.74 kPa)
Propane
13” W.C. (2.73 kPa)
If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is
adequately adjusted, and the total gas load for the residence does not exceed the amount supplied.
The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank)
should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the
regulator is at an improper pressure.