Operation
BAS-SVX08D-E4
36
Data
Type
Offset
Point Description
Function
Modbus
Index
30022
21
Circuit 1 % airflow
Percentage
30023
22
Circuit 2 % airflow
Percentage
30024
23
% line voltage chiller
Percentage
30025
24
Zone temperature
Temperature
30026
25
Outdoor air temperature
Temperature
30027
26
Compressor A phase A % RLA
Percentage
30028
27
Compressor A phase B % RLA
Percentage
30029
28
Compressor A phase C % RLA
Percentage
30030
29
Compressor B phase A % RLA
Percentage
30031
30
Compressor B phase B % RLA
Percentage
30032
31
Compressor B phase C % RLA
Percentage
30033
32
Compressor C phase A % RLA
Percentage
30034
33
Compressor C phase B % RLA
Percentage
30035
34
Compressor C phase C % RLA
Percentage
30036
35
Compressor D phase A % RLA
Percentage
30037
36
Compressor D phase B % RLA
Percentage
30038
37
Compressor D phase C % RLA
Percentage
30039
38
Active current limit setpoint
Percentage
30040
39
External chilled water setpoint
Temperature
30041
40
External current limit setpoint
Percentage
30042-30043
41-42
Compressor A running hours
Hours
30044-30045
43-44
Compressor B running hours
Hours
30046-30047
45-46
Compressor C running hours
Hours
30048-30049
47-48
Compressor D running hours
Hours
30050-30051
49-50
Compressor A starts counter
None
30052-30053
51-52
Compressor B starts counter
None
30054-30055
53-54
Compressor C starts counter
None
30056-30057
55-56
Compressor D starts counter
None
30058
57
Circuit 1 compressor suction refrigerant temperature
Temperature
30059
58
Circuit 1 sat evap refrigerant temperature
Temperature
30060
59
Circuit 1 sat cond refrigerant temperature
Temperature
30061
60
Circuit 2 compressor suction refrigerant temperature
Temperature
30062
61
Circuit 2 sat evap refrigerant temperature
Temperature
30063
62
Circuit 2 sat cond refrigerant temperature
Temperature
30064
63
Circuit 1 subcooled liquid refrigerant temperature
Temperature
30065
64
Circuit 2 subcooled liquid refrigerant temperature
Temperature
30066
65
Compressor A entering oil temperature
Temperature
30067
66
Compressor B entering oil temperature
Temperature
30068
67
Auxiliary temperature
Temperature
30069
68
Unit tonnage
tons
Analog
Inputs
4
Unit