52
CAUJ-SVX01E-EN
Maintenance
Monthly Maintenance
Air Handling Equipment
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
us
s V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diissc
co
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e s
se
errv
viic
ciin
ng
g cco
ou
ulld
d
rre
es
su
ulltt iin
n d
de
ea
atth
h o
orr s
se
erriio
ou
us
s iin
njju
urry
y..
D
Diisscco
on
nn
ne
ec
ctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diis
scco
on
nn
ne
eccttss b
be
effo
orre
e s
se
errv
viic
ciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
oc
ckko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
es
s tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
c
ca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
Before completing the following checks, turn the
system control circuit switch 1S2 and 5S1 to the "Off"
position. Open the main power disconnect switch for
the Condensing Unit and Air Handling Unit and "lock it"
in the "Off" position before removing any access
panels.
•
Inspect the return air filters. Clean or replace them if
necessary.
•
Check the evaporator drain pan and condensate
piping to ensure that there are no blockages.
•
Inspect the evaporator coils for dirt. If the coils
appear dirty, clean them according to the
instructions described in
““Coil Cleaning,” p. 56,” p.
53
.
•
Inspect the economizer damper hinges and pins (if
applicable) to ensure that all moving parts are
securely mounted. Clean the blades as necessary.
•
Verify that all damper linkages move freely.
Lubricate with white grease, if necessary.
•
Check Supply Fan motor bearings. Repair or replace
the motor as necessary.
•
Check the fan shaft bearings for wear. Replace the
bearings as necessary.
•
Lubricate supply fan bearings. Contact equipment
manufacturer for recommended greases.
N
NO
OT
TIIC
CE
E
B
Be
ea
arriin
ng
g D
Da
am
ma
ag
ge
e!!
O
Ov
ve
err llu
ub
brriicca
attiio
on
n c
co
ou
ulld
d rre
es
su
ulltt iin
n a
as
s m
mu
ucch
h d
da
am
ma
ag
ge
e
tto
o ffa
an
n b
be
ea
arriin
ng
gss a
ass n
no
ott e
en
no
ou
ug
gh
h g
grre
ea
asse
e..
T
To
o p
prre
ev
ve
en
ntt d
da
am
ma
ag
ge
e tto
o ffa
an
n b
be
ea
arriin
ng
gss,, d
do
o n
no
ott o
ov
ve
err
llu
ub
brriicca
atte
e..
IIm
mp
po
orrtta
an
ntt:: Use a hand grease gun to lubricate
bearings. Add grease until a light bead
appears all around the seal.
After greasing the bearings, check the
setscrews to ensure that the shaft is held
securely to the bearings and fan wheels.
Make sure that all bearing supports are
tight.
•
Check the supply fan belt(s). If the belts are frayed
or worn, replace them.
•
Verify that all wire terminal connections are tight.
•
Inspect unit for unusual conditions (e.g., loose
access panels, leaking piping connections, etc.)
•
When checks are complete, verify all retaining
screws are reinstalled in unit access panels.
Condensing Unit
W
WA
AR
RN
NIIN
NG
G
R
Ro
otta
attiin
ng
g C
Co
om
mp
po
on
ne
en
ntts
s!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ec
ctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n rro
otta
attiin
ng
g cco
om
mp
po
on
ne
en
nttss ccu
uttttiin
ng
g a
an
nd
d sslla
assh
hiin
ng
g
tte
ecch
hn
niicciia
an
n w
wh
hiic
ch
h cco
ou
ulld
d rre
es
su
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss
iin
njju
urry
y..
D
Diis
sc
co
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
ec
ctts
s b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
ns
su
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
•
Manually rotate the condenser fans to ensure free
movement and check motor bearings for wear.
Verify that all of the fan mounting hardware is tight.
•
Verify that all wire terminal connections are tight.
•
Inspect the condenser coils for dirt and foreign
debris. If the coils appear dirty, clean them
according to the instructions described in Coil
Cleaning section.
•
Inspect the compressor and condenser fan motor
contactors. If the contacts appear severely burned
or pitted, replace the contactor. Do not clean the
contacts.
•
Check the compressor oil level. (Compressors "Off")