CAUJ-SVX01E-EN
41
C
Ca
allccu
ulla
attiio
on
n —
— D
Diissc
co
on
nn
ne
ecctt S
Sw
wiittc
ch
h S
Siizziin
ng
g ((D
DS
SS
S))
•
DSS = 1.15 X (LOAD 1 + LOAD 2 + LOAD 4)
Field Installed Control Wiring
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
us
s V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diissc
co
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e s
se
errv
viic
ciin
ng
g cco
ou
ulld
d
rre
es
su
ulltt iin
n d
de
ea
atth
h o
orr s
se
erriio
ou
us
s iin
njju
urry
y..
D
Diisscco
on
nn
ne
ec
ctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diis
scco
on
nn
ne
eccttss b
be
effo
orre
e s
se
errv
viic
ciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
oc
ckko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
es
s tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
c
ca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
s
se
erriio
ou
us
s iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errs
so
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
ns
stta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
as
s d
de
essc
crriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
s
stta
atte
e e
elle
eccttrriicca
all cco
od
de
ess..
Before installing any connecting wiring, see drawings
Dimensions and Weights chapter for the electrical
access locations provided on the unit. Install
appropriately sized control wiring for the 115 volt
electrical components as required by the application.
Since the unit-mounted 115V control power
transformer (1T1) is provided on all units, it is not
necessary to run a separate 115 volt control power
source to the unit.
N
No
otte
e:: All 200/230V units are shipped with transformer
1T1 wired for 200 volt operation. If the unit is to
be operated on a 230V power supply, rewire the
transformer as shown on the unit schematic.
When the 115 volt control circuit is properly connected
to the field provided interlock contacts 5K1 for circuit #1
and 5K2 for circuit #2 (if applicable), proper condenser
fan cycling and ambient control for the remaining fans
is achieved with corresponding compressor operation.
N
No
otte
e:: All field wiring must conform to NEC guidelines
as well as state and local codes.
Night Setback
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
us
s V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ec
ctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diis
sc
co
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
ec
ctts
s b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
ns
su
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d..
If night setback operation is desired, connect a set of
normally open contacts (field provided) to the
appropriate terminals on the terminal board (7TB7), in
the unit’s control panel. Remove the factory installed
jumper at the terminal board when making the final
wiring termination. Refer to the field connection
diagram, numbers 2307-9122 (for 20 to 60 ton units)
and 2307-9144 (for 80 to 120 ton units) for details.