84
WX9 ASD Installation and Operation Manual
Input Terminal 10 (LI2) Function
Program
Terminal
Input Terminals
This parameter selects the functionality of the
LI2
discrete input terminal.
In addition, this input terminal must be specified as
Normally Open
or
Normally Closed
.
This setting assigns the function of the programmable
LI2
terminal to one of
the user-selectable functions listed in
.
Note:
The
Expansion IO Card Option 1
option board (P/N ETB003Z)
is required to use this terminal.
See the
Expansion IO Card Option 1
instruction manual (P/N 58685) for
additional information on the function of this terminal.
Direct Access Number — F120
Parameter Type —
Selection List
Factory Default —
No Function is
Assigned
Changeable During Run —
No
Input Terminal 11 (LI3) Function
Program
Terminal
Input Terminals
This parameter selects the functionality of the
LI3
discrete input terminal.
In addition, this input terminal must be specified as
Normally Open
or
Normally Closed
.
This setting assigns the function of the programmable
LI3
terminal to one of
the user-selectable functions listed in
.
Note:
The
Expansion IO Card Option 1
option board (P/N ETB003Z)
is required to use this terminal.
See the
Expansion IO Card Option 1
instruction manual (P/N 58685) for
additional information on the function of this terminal.
Direct Access Number — F121
Parameter Type —
Selection List
Factory Default —
No Function is
Assigned
Changeable During Run —
No
Input Terminal 12 (LI4) Function
Program
Terminal
Input Terminals
This parameter selects the functionality of the
LI4
discrete input terminal.
In addition, this input terminal must be specified as
Normally Open
or
Normally Closed
.
This setting assigns the function of the programmable
LI4
terminal to one of
the user-selectable functions listed in
.
Note:
The
Expansion IO Card Option 1
option board (P/N ETB003Z)
is required to use this terminal.
See the
Expansion IO Card Option 1
instruction manual (P/N 58685) for
additional information on the function of this terminal.
Direct Access Number — F122
Parameter Type —
Selection List
Factory Default —
No Function is
Assigned
Changeable During Run —
No
Содержание WX9 ASD
Страница 1: ...WX9 ASD Install Op Manual TOSHIBA WX9 ASD INSTALLATION OPERATION MANUAL DN 68940 000 March 2014 ...
Страница 2: ......
Страница 3: ...DN 68940 000 March 2014 WX9 ASD Installation Operation Manual ...
Страница 4: ......
Страница 12: ...iv WX9 ASD Installation and Operation Manual ...
Страница 213: ...WX9 ASD Installation and Operation Manual 201 Figure 32 WX9 ASD Enclosure Dimensions Dimensions are in in mm ...
Страница 225: ......