
Hardware Diagnostics
01. Diagnostic Test
139
02. Random address read
Reads data at random addresses.
11. SAF-TE Test
Tests the SAF-TE function and the status LED on the hard disk drives.
1
Use the arrow keys to highlight 11. SAF-TE Test on the Diagnostic Test menu.
2
Press Enter.
The following screen displays:
3
Using the arrow keys, select the SAF-TE test.
01. SAF-TE test
Detects the SAF-TE controller and checks the operation by flashing the LED for
each hard disk drive.
a
The test detects the SAF-TE controller first and shows the connecting
destination of the detected SAF-TE controller (host number, SCSI ID and
channel number) with model name.
--HT-ID----CH--VENDOR-PRODUCT-------FAN-PS--SLOT
XX XX XX XXXX XXXX
XX XX XX
b
After detecting the SAF-TE controller, the following message displays:
SAF-TE LED Steady ON (Faulty Flag)
Hit any key
Check that all LEDs on the hard disk drives are lit orange.
c
Press Enter. The following message displays:
SAF-TE LED Blinking (Rebuilding Flag)
Hit any key
Check that all LEDs on the hard disk drives are flashing orange.
d
Press Enter. The following message displays:
SAF-TE LED Steady On (Rebuild Interrupted)
Hit any key
Check that all LEDs on the hard disk drives are lit orange.
e
Press Enter. The following message displays:
SAF-TE LED Blinking (Rebuilding Flag)
Hit any key
Check that all LEDs on the hard disk drives are flashing orange.
f
Press Enter. The following message displays:
SAF-TE LED Reset (No Error Flag)
Hit any key
Содержание Magnia Z310
Страница 1: ......
Страница 19: ...19 ...
Страница 413: ...413 Other optional items Slot Maker Model No Type No Setting and others Date installed Serial port COM1 USB1 USB2 ...