GX9 ASD Quick Start Guide
Virtual Linear Pump Setup
Toshiba International Corporation’s
Virtual Linear Pump
algorithm allows for direct and precise
control of pressure, flow rate, or level. This is achieved without the concerns, instabilities, or
complexities that are traditionally associated with pumping system control. This section provides useful
setup and operational information for the
Virtual Linear Pump
system.
The system is initially configured using the (Program
Virtual Linear Pump
Setup Wizard
. Once
the Wizard
is started, it must be completed for normal
Virtual Linear Pump
operations to function.
However, the parameters addressed while using the Wizard or the
Virtual Linear Pump Settings
menu
selection are also accessible via their associated direct access numbers for specific adjustments when
required.
If using direct access numbers or the
Virtual Linear Pump
Settings
to configure the
Virtual Linear
Pump
algorithm, parameter
F911
must first be set to
255:Virtual Linear Pump
to accept the new or
changed
Virtual Linear Pump
parameter settings. Upon completion of the parameter changes, set
parameter
F911
to
1
or
2
to use the changed (new) settings for normal
Virtual Linear Pump
operations
(Zero may be selected at
F911
to save the changes to be used later).
The setup procedure and the Wizard setup screens are shown below.
Figure 26. Input the Electrical Specifications of the Motor.
Figure 27. Input the Specifications of the Transducer.
up Wizar
d
1. From the nameplate of the motor,
enter the FLA.
2. Select
Pressure
,
Flow
, or
Level
.
3. Select the command source:
EOI
,
VI/
II
,
RR
, or
Com. Opt
.
4. Set the
Low Frequency Limit
. 15 Hz
fits most applications.
5. Click
Next
to continue.
6. Set the unit of measure for the
transducer: pressure, flow rate, or
level (i.e., PSI, GPM, Inches of Water
Column, Feet of Water Column, or
Cubic Feet per Minute, °C, °F, or
Custom).
7. Select the transducer output signal
type: current or voltage and the range.
8. Set the maximum reading of the
transducer.
9. Set the minimum reading of the
transducer.
10.Click
Next
to continue.
Note:
The
Custom
selection allows for a
user-created unit of measure for
the process variable as measured
by the transducer.
Содержание GX9 ASD
Страница 1: ...GX9 ASD Quick Start Guide TOSHIBA GX9 ASD Quick Start Guide DN 66900 001 March 2014 ...
Страница 2: ......
Страница 3: ...Document Number 66900 001 March 2014 GX9 ASD Quick Start Guide ...
Страница 4: ......
Страница 88: ...78 GX9 ASD Quick Start Guide Figure 33 GX9 ASD 5 0 20 HP Enclosure ...
Страница 89: ...GX9 ASD Quick Start Guide 79 Figure 34 GX9 ASD 25 75 HP Enclosure ...
Страница 90: ...80 GX9 ASD Quick Start Guide Figure 35 GX9 ASD 100 200 HP Enclosure ...
Страница 91: ...GX9 ASD Quick Start Guide 81 Figure 36 GX9 ASD 250 400 HP Enclosure ...
Страница 92: ...82 GX9 ASD Quick Start Guide Figure 37 GX9 ASD 500 800 HP Enclosure ...
Страница 93: ...GX9 ASD Quick Start Guide 83 Figure 38 GX9 ASD 900 1200 HP Enclosure ...
Страница 99: ......