![Toshiba GX9 ASD Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/toshiba/gx9-asd/gx9-asd_quick-start-manual_424980042.webp)
32
GX9 ASD Quick Start Guide
EOI Command (RS232/RS485) Menu
The
Command (RS232/RS485)
menu is accessed by pressing
ESC
from the
Frequency Command
screen. The control settings of the
Command (RS232/RS485)
menu are effective for
EOI
control only.
The
Command (RS232/RS485)
menu provides quick access to the following menu parameters:
Direction
—
Forward
or
Reverse
.
Stop Pattern
— The
Decel Stop
or
Coast
Stop
settings
determines the method used to stop the motor
when using the
Stop|Reset
key of the
EOI
. The
Decel Stop
setting enables the
Dynamic Braking
system setup at
F304
or the
DC Injection Braking
system setup at
F250
,
F251
, and
F252
. The
Coast
Stop
setting allows the motor to stop at the rate allowed by the inertia of the load.
Note:
The
Stop Pattern
setting has no effect on the
Emergency Off
settings of
F603
.
V/f Group
— 1 of 4
V/f
profiles may be selected and run. Each
V/f
profile is comprised of 4 user
settings:
Base Frequency
,
Base Frequency Voltage
,
Manual Torque Boost
, and
Motor Overload
Protection
. Expanded descriptions of these parameters may be found in the section titled Direct
Access Parameter Information in the
GX9 ASD Installation & Operation Manual
.
Accel/Decel Group
— 1 of 4
Accel/Decel
profiles may be selected and run. Each of the
Accel/Decel
profiles is comprised of 3 user settings:
Acceleration
,
Deceleration
, and
Pattern
. Expanded
descriptions of these parameters may be found in the section titled Direct Access Parameter
Information in the
GX9 ASD Installation & Operation Manual
.
PID Control
— This feature enables or disables the
PID
feedback function.
Torque Limit Group
— This parameter is used to select 1 of 4 preset positive torque limits to apply
to the active motor (of a multiple motor configuration). The settings of profiles 1 – 4 may be setup at
F441
,
F444
,
F446
, and
F448
, respectively.
VLP Technology Control
— This feature enables or disables the
Virtual Linear Pump
function.
Содержание GX9 ASD
Страница 1: ...GX9 ASD Quick Start Guide TOSHIBA GX9 ASD Quick Start Guide DN 66900 001 March 2014 ...
Страница 2: ......
Страница 3: ...Document Number 66900 001 March 2014 GX9 ASD Quick Start Guide ...
Страница 4: ......
Страница 88: ...78 GX9 ASD Quick Start Guide Figure 33 GX9 ASD 5 0 20 HP Enclosure ...
Страница 89: ...GX9 ASD Quick Start Guide 79 Figure 34 GX9 ASD 25 75 HP Enclosure ...
Страница 90: ...80 GX9 ASD Quick Start Guide Figure 35 GX9 ASD 100 200 HP Enclosure ...
Страница 91: ...GX9 ASD Quick Start Guide 81 Figure 36 GX9 ASD 250 400 HP Enclosure ...
Страница 92: ...82 GX9 ASD Quick Start Guide Figure 37 GX9 ASD 500 800 HP Enclosure ...
Страница 93: ...GX9 ASD Quick Start Guide 83 Figure 38 GX9 ASD 900 1200 HP Enclosure ...
Страница 99: ......