g005083
Figure 34
1.
Main harness connector
2.
Jumper wire
6.
Install the main harness connector to the main
harness (
7.
Install the control panel to the machine.
g003648
Figure 35
1.
Switch
4.
Switch connector
2.
Screw
5.
Main harness connector
3.
Control panel
Install the fuse into right slot in the fuse block
(
).
8.
Install the square connector to the relay installed
next with the valve (
9.
Install the small connector to the valve (
10.
Fasten the wire harness to the valve with a
cable tie.
g003620
Figure 36
1.
Valve
4.
Cable tie
2.
Small connector
5.
Relay
3.
Diode
6.
Square connector
13
Installing the Hydraulic
Fluid and Checking for
Leaks
Parts needed for this procedure:
1
Dipstick
25.5 L
(6-3/4
US
gallons)
Hydraulic fluid
Procedure
The hydraulic system capacity is now 25.5 L (6-3/4
US gallons).
Refer to the
Operator's Manual
for the correct fluid
to use.
1.
Remove the old dipstick from the hydraulic tank
and discard.
2.
Slowly pour approximately 80% of the specified
fluid into the tank.
16