g018784
Figure 32
1.
Small 90-degree tee with
barb in hydraulic tank
4.
Hydraulic line number 4
2.
Small hose clamp
5.
Hydraulic line (hose)
number 5
3.
Small molded hose
11
Tightening All Connections
No Parts Required
Procedure
Note:
Make sure that the hoses and hydraulic lines
are routed away from and to do not rub against any
sharp, hot, or moving components.
1.
When all hydraulic lines and hoses are installed,
tighten all of the connections.
Note:
Use a backup wrench on all tank fittings.
2.
Position the coupler bracket as close to the left
tire as possible and tighten the clamps.
12
Installing the Switch and
Harness
Parts needed for this procedure:
1
Harness
1
Switch
1
Fuse
Procedure
1.
Remove the control panel from the machine.
2.
Remove the plastic plug from the panel and
install the switch to the panel (
).
3.
Route the harness along the seat hinge from the
switch and to the relay previously installed to
the valve (
).
g003649
Figure 33
1.
Small connector
5.
Main harness connector
2.
Square connector
6.
Switch connector
3.
Seat hinges
7.
Cable tie
4.
Fuse block
4.
Install the harness to the switch in the control
panel (
).
5.
Remove the jumper wire from the main harness
under the control panel (
).
15