50
FULLY BIOLOGICAL MINI SEWAGE TREATMENT PLANT FOR YACHTS, HOUSEBOATS AND MOBILE HOMES
enteron | User Manual
Function
Switch of the remote control
Filling level reached in the collection tank, it should be manually pum-
ped out by a short turn on OUT
(in automatic mode this happens
without user intervention!)
. This switch is only active in
MANUAL-
LY
mode. After a short turn of the switch to
OUT
, the disinfection and
emptying cycle is started.
CAUTION:
Also, in
AUTOMATIC
(standard)
mode, the red LED flashes quickly until the tank has been pumped out.
This is a normal function of the plant and a malfunction only occurs if it
is lit up for a longer period without pumping in standard mode. To do
this, first pump out manually to check the function of the pump.
OUT
Emptying
LED-Display
off or
RED
Function
Switch of the remote control
By turning the switch to
MANUALLY
mode, automatic emptying of the
tank is prevented, a red LED in the lower pump switch indicates the
level reached. This mode also activates the underneath located switch
for the pumps.
MANUALLY
Manual operating mode
LED-Display
GREEN
Function
Switch of the remote control
By turning the switch shortly to the MAC position, the plant is manually
pumped out. This is necessary once a week for maintenance or in case
of impending clogging and sludge avoidance. This switch is only active
in
MANUALLY
mode
MAC
Pump out
LED-Display
off or
RED
EXPLANATION OF THE OPERATING ELEMENTS AND
DISPLAYS ON THE REMOTE CONTROL
enteron
control