51
FULLY BIOLOGICAL MINI SEWAGE TREATMENT PLANT FOR YACHTS, HOUSEBOATS AND MOBILE HOMES
enteron | User Manual
Function
Switch of the remote control
The plant can be operated in overload mode for a few days if there are
more people on board than expected (guest mode) or to prepare for
the shutdown of the plant. The faeces are often circulated here, which
speeds up processing. In this mode, more energy is used than in nor-
mal operation.
OVERLOAD
Overload operation
LED-Display
GREEN
Function
Switch of the remote control
A fast flashing LED indicates an overpressure situation in the collection
tank, which can be caused by clogging or full tanks. First check whether
the tank is overfilled (red LED next to the pump switch) and empty it
manually in
MANUALLY
mode. If this does not eliminate the overpres-
sure situation, you can pump the system several times with
MAC
in
MANUALLY
mode.
The
RESET
button is also used to acknowledge all error and maintenan-
ce messages displayed on the control display. After the maintenance
work has been carried out, you can confirm the notification by pressing
this key. This key has no function without message on the display.
ALARM RESET
LED-Display
RED
Flashing every 5 seconds
indicates standard operation
without error.
Rapid flashing indicates an
overpressure situation, which
the system immediately
tries to eliminate automati-
cally by recirculation.
Only if the overpressure
remains, a red error message
appears on the display.
Continuous lightning means
a message on the display of
the display of the PLC control
system, which requires
immediate checking of the
error message.