9
Temperature Measurement & Face Recognition Terminal User Manual
3
Temp Measurement & FR Config
3.1 Temperature Measurement Settings
After the network is connected, go to the web client. Click Config
→
Temperature
Measurement to go to the following interface.
1.
Enable
“
Temperature Measurement
”
, select Celsius or Fahrenheit temperature as
needed and then set the high temperature threshold and the low temperature threshold. When
the body temperature measured is higher or lower than the set value, it will trigger alarms.
2.
Set the alarm holding time.
3.
Set the alarm trigger options.
Trigger Alarm Out:
If enabled, the alarm output device will be triggered when detecting
abnormal temperature.
Trigger Audio Alarm
: If enabled, the system will broadcast the current body temperature on
detecting a body. No matter whether the detected body temperature is normal or not, the
corresponding voice prompt will be heard. If this item is disabled, the detected temperature will
be not broadcasted.
Trigger SD Snap
: If enabled, the system will capture images on detecting abnormal