F 2 function
11
Deactivate external triggering
1. The power control unit is switched on
(left LED lights up in red, yellow or green after selecting F 1)
2. Place the
fl
ip switch in the central position
3. Press both the function keys F 1 and F 2 at the same time and keep them pressed down
4. Turn the control knob in such a way until no point lights up green and orange in the
illumination ring
5. Release both function keys F 1 and F 2 again
6. Programming complete
external triggering is now deactivated
Note: Whenever an option has been changed the dwell time and delay/acceleration
must also be reprogrammed.
Programming the dwell time
1. The power control unit is switched on
(left LED lights up in red/yellow or green depending on the mode)
2. Place the
fl
ip switch in the central position
3. Press the function key F 2 and keep it pressed down
4. Turn the control knob until the desired number of points lights up
in the illumination ring:
5. Release the function key F 2 again
6. Programming complete
the desired dwell time is now set
no point green (power control unit value approx. 0 – 5)
1 point green (power control unit value approx. 10 – 15)
2 points green (power control unit value approx. 20 – 25)
3 points green (power control unit value approx. 30 – 35)
4 points green (power control unit value approx. 40 – 50)
5 points green (power control unit value approx. 50 – 60)
6 points green (power control unit value approx. 60 – 70)
7 points green (power control unit value approx. 75 – 85)
8 points green (power control unit value approx. 85 – 95)
9 points green (power control unit value approx. 95 – 105)
10 points green (power control unit value approx. 105 – 120)
5 s dwell time
5 s dwell time
10 s dwell time
15 s dwell time
20 s dwell time
25 s dwell time
30 s dwell time
40 s dwell time
50 s dwell time
60 s dwell time
Inde
fi
nite dwell time