Place battery module in the enclosure then slide the
brackets inward on each side of the battery and
tighten the wingnuts to secure.
Wiring the battery modules (Battery enclosure 1)
CAUTION!
Do not reverse the positive and negative of the battery input terminals.
Note:
The battery conductors and communications cables are labeled and located
inside the enclosure. Carefully cut cable ties and connect as shown. When
properly installed a
“click” will be heard.
Three types of cables are located inside the EI Battery enclosure:
•
The
PCS
communication cable is used to connect the batteries to the Battery
Management System (BMS) inside the EI Battery enclosure. Only one battery module 1
(upper battery) is connected directly to the BMS in a single EI Battery installation.
•
The battery modules are connected in series by the
Link-In
and
Link-Out
communications cables.
•
The battery modules are wired together for power using the
BAT+
and
BAT-
conductors.
Note:
The battery module serial numbers will be needed later during the commissioning
and warranty completion. The serial is provided on the battery module as well as
its box. Note which battery is installed in each position on the respective box.
Figure 17 Mounting the
battery modules