77210163GB Issue 3
36
3.6.6.2 fine Orientation head
Unscrew the shaft on the Quick Release Clamp to remove it. Screw the Quick Release
Clamp onto the shaft in the centre of the Fine Orientation Head and turn the Orientation
Clamp (c) on the right hand side of the Orientation Head away from you to secure the
Clamp.
c
b
a
To adjust the up-to-down and left-to-right orientation of the specimen before sectioning
takes place, turn the Orientation Clamp towards you to unlock the clamp.
Use the knurled rotary control (b) at the top of the Orientation Head to set the vertical
orientation of the specimen. Clockwise rotation tilts the specimen upward; counter-
clockwise rotation tilts the specimen downward.
Use the knurled rotary control (a) at the left hand side of the Orientation Head to set the
horizontal orientation of the specimen. Clockwise rotation tilts the specimen to the left;
counter-clockwise rotation tilts the specimen to the right.
Turn the Orientation Clamp away from you (clockwise) to lock the specimen in the
required position.
Содержание Cryotome