D2/D4 Heater Duct Installation (continued)
Discharge Air
1.
Find an appropriate location for the floor level
discharge air vent
and drill a
2-1/2”
hole using the correct
hole saw.
a.
Unsnap rotating outer louver assembly from the mounting base.
b.
Install the base into 2-1/2” hole and secure with supplied screws.
c.
Reinstall rotating outer louver assembly back into the mounting base ring. Verify that it rotates freely.
2.
Attach one end of the heater duct to the discharge outlet hood on the heater and secure with supplied clamp.
3.
Route the heater duct to the floor level discharge air vent, cut as needed, attach to the end of the plastic louver
vent and secure with supplied hose clamp.
Return Air
4.
If a return air duct is not used, the protective grille must be installed onto the heater inlet.
5.
Find an appropriate location for the floor level
return air grille
and drill a
2-1/2”
hole using the correct hole
saw.
a.
Install the return air grille into the 2-1/2” hole and secure with supplied screws.
6.
Attach one end of the return air duct to the air inlet hood on the heater and secure with supplied clamp.
a.
Route the return air duct to the return air grille, cut as needed, attach to the end of the plastic
louver vent and secure with supplied hose clamp.
Figure 20: Discharge and Return Air Duct Installation
Содержание TriPac Envidia
Страница 2: ......
Страница 11: ...9 Battery Box Dimensions Figure 1 Battery Box Dimensions...
Страница 12: ...10 Battery Box Dimensions continued Figure 2 Battery Box Dimensions continued...
Страница 13: ...11 Evaporator Control Box Dimensions Figure 3 Evaporator Control Box Dimensions...
Страница 14: ...12 Condenser with Receiver Drier Dimensions Figure 4 Condenser with Receiver Drier Dimensions...
Страница 15: ...13 HMI Dimensions Figure 5 HMI Dimensions...
Страница 16: ...14 1000 Watt Power Inverter Dimensions Option Figure 6 1000 Watt Power Inverter Dimensions...
Страница 17: ...15 AC DC Shore Power Converter Dimensions Option Figure 7 AC DC Shore Power Converter Dimensions...
Страница 18: ...16 D2 D4 Heater Dimensions Option Figure 8 Heater Dimension...
Страница 19: ...17 BLANK PAGE...
Страница 21: ...19 Typical Component Locations Figure 9 Typical Component Locations...
Страница 45: ...43 A C Duct Installation continued FLUSH MOUNTED EVAPORATOR Figure 21 A C Duct locations...
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 79: ......