Operating Instructions Premium HMI
6-16
MAIN MENU OVERVIEW (SPECTRUM)
Truck TSR-2/3 SPECTRUM M/T Operator and Main Menu.
MAIN MENU CHOICES
LANGUAGE
- If more than one language is enabled, this will be the first menu item to appear. If only one language is
enabled, this menu will not appear. The Language Menu allows the operator to select a language from a list of up to 11 languages
at one time. All subsequent displays are shown in the selected language. Three different language packages with a total of 23
languages are available. English is the default language and is provided in each of the packages.
ALARMS
- Allows the operator to view all alarms, and allows most alarms to be cleared. If only one language is enabled this
will be the first menu item to appear.
DATA LOGGER
- Allows the operator to set a Start of Trip marker to the ServiceWatch data logger. Also allows a Start of
Trip and Print requests to be sent to the Optional DAS Data Logger (if installed).
HOURMETERS
- Allows the operator to view the unit hourmeters that have the view feature enabled in the Guarded Access
menu. If the view feature for a particular hourmeter is not enabled then that hourmeter will continue to accumulate time but
cannot be viewed from the Main Menu. However, all hourmeters can be viewed from the Maintenance Menu, even if they are
not enabled.
MODE
- Allows the operator to change the unit operating modes if allowed. Not all modes may appear depending on the
settings selected from the Guarded Access menu and the HMI Control Panel software version.
• "Turn Off CYCLE-SENTRY Mode/Turn On CYCLE-SENTRY Mode (If CYCLE-SENTRY is Off unit runs in Continuous).
• Allow Keypad Lockout to be selected.
• Start Sleep Mode.
PRETRIP
- Allows the operator to start a Pretrip Test. If an alarm is active, the Pretrip Test is not allowed and the operator
is prompted to clear the alarm(s).
ELECTRIC STANDBY
- If the Electric Standby option is present and the Diesel to Electric Auto-switch feature is set NO,
this feature allows the operator to manually select electric mode operation. This feature does not appear if the unit does not feature
optional Electric Standby or if the Diesel to Electric Auto-switch feature is set YES.
DIESEL MODE
- If a unit equipped with electric standby is running in electric mode and the Electric to Diesel Auto-switch
feature is set NO, this feature allows the operator to manually select diesel mode operation. This feature does not appear if the
unit does not feature optional Electric Standby or if the Electric to Diesel Auto-switch feature is set YES.
ADJUST BRIGHTNESS
- Allows the operator to adjust the HMI Control Panel display backlight intensity as required by
local conditions.
TIME
- Allows the operator to view the unit time and date. The time and date cannot be changed from this menu.
LANGUAGES
If the Language feature is enabled, an alternate language can be selected from the Language Menu. After a new language is
chosen, all subsequent displays will appear in that language. If the language feature is not enabled this menu does not appear.
The default language is English. Only languages that have been enabled in Guarded Access will appear. Exercise care when
changing languages, as once changed all HMI Control panel displays will be in the new language. If the user is not familiar with
the new language, problems may be experienced returning to the default language.
The languages available are dependent on the HMI control panel software revision.
• Languages currently supported by software revision 65xx are English, Spanish, French, German, Italian, Dutch, Portuguese,
Greek, Turkish, Hebrew and Arabic.
• Languages currently supported by software revision 66xx are English, Danish, Russian, Norwegian, Swedish, Finnish, Polish,
Hungarian, Romanian, Bulgarian and Czech.
• Languages currently supported by software revision 67xx are English, Japanese and Chinese. Other than the languages
supported, software revisions 65xx, 66xx and 67xx are functionally identical.
To select an alternate language, press the MENU
key.(Figure "Menu Key" page 6-15)
Содержание T-1000R
Страница 14: ...Safety Precautions 2 6 Warning Decals 2e24151g0 ...
Страница 18: ...Specifications 3 4 ENGINE CLUTCH Engagement 600 100 RPM Dynamic Torque 66 fT lb 89 5 N m minimum 1600 RPM ...
Страница 34: ...Maintenance Inspection Schedule 4 10 ...
Страница 57: ...Unit Description 5 23 Purge Mode UT Series 1 3 4 5 2 ...
Страница 67: ...Unit Description 5 33 Zone 1 Cool and Zone 2 Cool UT SPECTRUM Units ...
Страница 69: ...Unit Description 5 35 Purge Mode UT SPECTRUM Units ...
Страница 71: ...Unit Description 5 37 Zone 1 Cool and Zone 2 Heat UT SPECTRUM Units ...
Страница 72: ...Unit Description 5 38 ...
Страница 74: ...Diesel Electric Menu 6 28 Adjust Brightness 6 29 Time 6 30 ...
Страница 120: ...Operating Instructions Standard HMI 7 18 ...
Страница 152: ...Engine Maintenance 9 14 T Series Fuel and Oil System Components TK 376 ...
Страница 154: ...Engine Maintenance 9 16 T Series Fuel and Oil System Components TK 270 ...
Страница 156: ...Engine Maintenance 9 18 UT Series Fuel System Components AMA768 ...
Страница 172: ...Engine Maintenance 9 34 T Series Engine Mounting Components for 2 Cylinder Engine ...
Страница 184: ...Engine Maintenance 9 46 ...
Страница 238: ...Refrigeration Maintenance 10 54 ...
Страница 246: ...Clutch Maintenance 11 8 ...
Страница 258: ...Structural Maintenance 12 12 ...
Страница 264: ...Mechanical Diagnosis 13 6 ...
Страница 265: ...14 Electric Standby Diagnosis ...
Страница 268: ...Electric Standby Diagnosis 14 4 ...
Страница 269: ...15 Refrigeration System Diagnosis ...
Страница 272: ...Refrigeration System Diagnosis 15 4 ...
Страница 280: ...Remote Evaporators 16 8 ...
Страница 282: ...Wiring Diagrams and Wiring Schematics 17 2 ...